HVAC TRUE RMS MULTIMETER FLUKE

HVAC TRUE RMS MULTIMETER FLUKE

TRUE RMS ELECTRONIC LOGGING MULTIMETER WITH TREND CAPTURE FLUKE

TRUE RMS ELECTRONIC LOGGING MULTIMETER WITH TREND CAPTURE FLUKE

ELECTRICIANS TRUE RMS MULTIMETER FLUKE

Designed by electricians. Engineered by Fluke. Compact true-rms meter for commercial applications. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster. Also check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 116 HVAC Multimeter with Temperature and Microamps. VoltAlert™ technology for non-contact voltage detection AutoVolt automatic ac/dc voltage selection Low input impedance: helps prevent false readings due to ghost voltage Large white LED backlight to work in poorly lit areas True-rms for accurate measurements on non-linear loads Measures 10 A (20 A overload for 30-seconds) Resistance, continuity, frequency and capacitance Min/Max/Average with elapsed time to record signal fluctuations Compact ergonomic design for one-handed operation Compatible with optional magnetic hanger (ToolPak™) for hands free operation CAT III 600 V safety rated Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 Fuse for A input 11 A, 1000 V FAST Fuse (Fluke PN 803293) Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 °C to + 50 °C Storage Temperature -40 °C to + 60 °C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 Auto volts Range: 600.0 V Resolution: 0.1 V Accuracy: 2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) Continuity Range: 600 Ω Resolution: 1 Ω Accuracy: Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. Ohms Range/Resolution: 600.0 Ω / 0.1 Ω Range/Resolution: 6.000 kΩ / 0.001 kΩ Range/Resolution: 60.00 kΩ / 0.01 kΩ Range/Resolution: 600.0 kΩ / 0.1 kΩ Range/Resolution: 6.000 MΩ / 0.001 MΩ Accuracy: 0.9 % + 1 Range/Resolution: 40.00 MΩ / 0.01 MΩ Accuracy: 5 % + 2 Diode Test Range/Resolution: 2.000 V / 0.001 V Accuracy: 0.9% + 2 Capacitance Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 μF / 0.01 μF Range/Resolution: 100.0 μF / 0.1 μF Range/Resolution: 9999 μF / 1 μF Range/Resolution: 100 μF to 1000 μF Accuracy: 1.9% + 2 Range/Resolution: > 1000 μF Accuracy: 5% + 20% LoZ capacitance Range: 1 nF to 500 μF Accuracy: 10% + 2 typical AC amps true-rms (45 Hz to 500 Hz) Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.5% + 3 20 A continuous overload for 30 seconds max DC amps Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.0% + 3 20 A continuous overload for 30 seconds max Hz (V or A input)2 Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.99 Hz / 0.1 Hz Range/Resolution: 9.999 Hz / 0.001 Hz Range/Resolution: 50.00 Hz / 0.01 Hz Accuracy: 0.1% + 2 Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F Mechanical & General Specifications Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") Weight 550 g Electrician’s Multimeter with Non-Contact Voltage Model includes the following: 4 mm silicone test lead set Holster User manual
Item# FLUKE-117
$252.99

Ships in 1-2 weeks

People who viewed this product also viewed: