The Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its’ unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke 287 packs more accuracy and convenience into a handheld multimeter than ever before, putting more problem solving power in your hands. It is the ultimate handheld tool for demanding applications that require high-precision.
Key Features Include:
New with V 1.1 Upgrade! Zoom on trend provide unprecedented ability to view analyze TrendCapture data; see detail at X5 magnification.
New with V 1.1 Upgrade! Simplified Record screen when setting up recording
New with V 1.1 Upgrade! Logging function with expanded memory for unattended monitoring of signals over time. Using on-board TrendCapture users can graphically review logged readings without needing a PC. Store up to 15,000 recorded events.
Large 50,000 count, ¼ VGA display with white backlight. Multiple sets of measurement information can simultaneously be displayed at the same time.
Logging function with TrendCapture is an essential tool for documenting the performance of your designs, processes or systems, or unattended monitoring while you work on other projects. It plots measurements as a single line to help detect signal anomalies over time. Using on-board TrendCapture, you can graphically view logged readings without a PC. (Software and interface cable optional).
Log multiple sessions or log data continuously for over 200 hours.
i-info button. On board help screens for measurement functions. Unsure about a function? Go to that function and Press the “i” button.
Now, name your saved measurements and also recall measurements made in the field
Real Time Clock – for automatic time stamping of saved readings
Field upgradeable and expandable meter lets you stay current as new capabilities are added
Multi-lingual interface
Min/Max/Average with Time Stamp to record signal fluctuations
Soft keys, scroll buttons and easy navigation control access to secondary functions.
0.025% Basic DC accuracy
100 kHz ac bandwidth
True-rms ac voltage and current for accurate measurements on complex signals or non-linear loads.
Measure up to 10A (20 A for 30 seconds; 10A continuous)
100 mF capacitance range
Temperature function
Relative mode to remove test lead resistance from low ohms or capacitance measurements
Peak capture to record transients as fast as 250 μs
Premium test leads and alligator clips included
Optional FlukeView forms enables you to document, store and analyze individual readings or a series of measurements, then convert them into professional-looking documents
Optional magnetic hanger allows you to hang the meter for easy viewing while freeing your hands to focus on the job.
Limited lifetime warranty
CAT III 1000 V / CAT IV 600 V safety rated
Specifications
Voltage DC
Accuracy 0.025 %
Range and Resolution 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Voltage AC
Accuracy 0.4 %(true-rms)
Range and Resolution 50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0V
Current DC
Accuracy 0.06 %
Range and Resolution 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Current AC
Accuracy 0.6%(true-rms)
Range and Resolution 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Temperature (excluding probe)
Accuracy 1.0 %
Range and Resolution -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F)
Resistance
Accuracy 0.05 %
Range and Resolution 500.00 Ω, 5.0000 kΩ, 50.000 kΩ, 500.00 kΩ, 5.0000 MΩ, 50.00 MΩ, 500.0 MΩ
Capacitance
Accuracy 1.0 %
Range and Resolution 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF
Frequency
Accuracy 0.005% + 5
Range and Resolution 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Additional functions/features
Multiple on-screen displays Yes
True-rms AC bandwidth 100 kHz
DBV/dBm Yes
Conductance 50.00nS
Continuity beeper Yes
Battery/Fuse access Battery / Fuse
Peak 250 μS
Elapse time clock Yes
Time of day clock Yes
Min-Max-Avg Yes
Duty Cycle 0.01 % to 99.99 %
Pulse Width 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
Hold Yes
Isolated Optical Interface Yes
Auto/Touch Hold Yes
Reading memory Yes
Log to PC Yes
Interval/Event Logging Yes
Logging Memory Up to 10,000 readings
Environmental Specifications
Operating Temperature
-20 °C to +55 °C
Storage Temperature
-40 °C to +60 °C
Relative Humidity
0% to 90% (0 °C - 37 °C)
0% to 65% (37 °C - 45 °C),
0 to 45 % (45 °C - 55 °C
Electromagnetic Compatability
EMC EN6 1326-1
Vibration
Random vibration per MIL-PRF-28800f Class 2
Shock
1 meter drop per IEC/EN 61010-1 2nd edition
Safety Specifications
Overvoltage category
CAT III 1000 V / CAT IV 600 V safety rated
Agency Approvals
CSA, UL, TÜV, CE
Mechanical & General Specifications
Maximum voltage between any terminal and earth ground
1000V
Size
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38 in)
Weight
870.9 g (28 oz)
Battery Life
100 minimum, 200 hours in logging mode
Battery type
6 AA alkaline batteries, NEDA 15A IEC LR6
Item# FLUKE-287