ELECTRICALTRUE RMS MULTIMETER FLUKE

ELECTRICALTRUE RMS MULTIMETER FLUKE

HVAC TRUE RMS MULTIMETER FLUKE

HVAC TRUE RMS MULTIMETER FLUKE

TRUE RMS MULTIMETER FLUKE

Designed by electricians. Engineered by Fluke. Compact true-rms meter for field service technicians. The Fluke 115 is the solution for a wide variety of electrical and electronic testing applications. Also check out the Fluke 114 Electrical Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage. Large white LED backlight to work in poorly lit areas Resistance and continuity Min/Max/Average to record signal fluctuations CAT III 600 V safety rated Safety conformance All inputs are protected to CE, IEN61010-1 CAT III 600V. UL, CSA, TÜV listed and VDE. Specifications Maximum voltage between any terminal and earth ground 600 V Surge protection 6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2 Display Digital: 6,000 counts, updates 4 per second Bar graph 33 segments, updates 32 per second Operating Temperature -10 °C to + 50 °C Storage Temperature -40 °C to + 60 °C Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 Battery Life 400 hours typical, without backlight Accuracy Specifications DC millivolts Range: 600.0 mV Resolution: 0.1 mV Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 DC volts Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.00 V / 0.1 V Accuracy: ± ([% of reading] + [counts]): 0.5% + 2 AC millivolts1 true-rms Range: 600.0 mV Resolution: 0.1 mV Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) AC volts1 true-rms Range/Resolution: 6.000 V / 0.001 V Range/Resolution: 60.00 V / 0.01 V Range/Resolution: 600.0 V / 0.1 V Accuracy: 1.0 % + 3 (dc, 45 Hz to 500 Hz)2.0 % + 3 (500 Hz to 1 kHz) Continuity Range: 600 Ω Resolution: 1 Ω Accuracy: Beeper on < 20 Ω, off > 250 Ω; detectsopens or shorts of 500 μs or longer. Ohms Range/Resolution: 600.0 Ω / 0.1 Ω Range/Resolution: 6.000 kΩ / 0.001 kΩ Range/Resolution: 60.00 kΩ / 0.01 kΩ Range/Resolution: 600.0 kΩ / 0.1 kΩ Range/Resolution: 6.000 MΩ / 0.001 MΩ Accuracy: 0.9 % + 1 Range/Resolution: 40.00 MΩ / 0.01 MΩ Accuracy: 5 % + 2 Diode Test Range/Resolution: 2.00 V / 0.001 V Accuracy: 0.9% + 2 Capacitance Range/Resolution: 1000 nF / 1 nF Range/Resolution: 10.00 µF / 0.01 µF Range/Resolution: 100.0 µF / 0.1 µF Range/Resolution: 9999 µF / 1 µF Range/Resolution: 100 µF to 1000 µF Accuracy: 1.9% + 2 Range/Resolution: > 1000 µF Accuracy: 5% + 20% Lo-Z Capacitance Range: 1 nF to 500 µF Accuracy: 10% + 2 typical AC amps true-rms (45 Hz to 500Hz) Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.5% + 3 20 A overload for 30-seconds max DC amps Range/Resolution: 6.000 A / 0.001 A Range/Resolution: 10.00 A / 0.01 A Accuracy: 1.0% + 3 20 A overload for 30-seconds max Hz (V or A input)2 Range/Resolution: 99.99 Hz / 0.01 Hz Range/Resolution: 999.9 Hz / 0.01 Hz Range/Resolution: 9.999 kHz / 0.001 kHz Range/Resolution: 50 kHz / 0.01 kHz Accuracy: 0.1% + 2 Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F 2) Frequency is ac coupled, 5Hz to 30 kHz for ac voltage Mechanical & General Specifications Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82") Weight 550 g Warranty 3 years Model includes the following: Holster Installed 9 V battery 4 mm silicone test lead set User manual
Item# FLUKE-115
$233.99

Ships in 1-2 weeks

People who viewed this product also viewed: