Analog Multimeter, Volt Ohm Meter

Analog Multimeter, Volt Ohm Meter

ELECTRICALTRUE RMS MULTIMETER FLUKE

ELECTRICALTRUE RMS MULTIMETER FLUKE

UTILITY MULTIMETER FLUKE

True-rms Digital Multimeter designed for basic electrical tests The Fluke 113 Digital Multimeter gives users the means to quickly and easily do basic meter set and reconnect testing. This meter is simple-to-use and has the features needed to repair most electrical problems. The Fluke 113 has significant improvements over other digital multimeters available on the market, including Fluke model 7-600. Using the Fluke VCHEK™ LoZ low impedance measurement function, users can simultaneously test for voltage or continuity. The Min/Max function lets you record signal fluctuations. The Fluke 113 can perform diode tests, and also provides both auto and manual ranging capabilities. With features such as conformance to the latest safety standards, backlight, and a much larger display that’s easier to view, this meter is a must have for every toolbox. Features and benefits of the Fluke 113 VCHEK™ LoZ low impedance measurement function to simultaneously test for voltage or continuity True-rms for accurate ac measurements on non-linear loads A large backlit display allows for easy visibility in low-lit areas Record signal fluctuations using the Min/Max function Diode test for testing general-purpose germanium, silicon, and power diodes Integral holster with probe holders for easy storage Auto and Manual ranging for added user functionality Meets Measurement Category CAT III 600 V and Category IV 300 V standards for a higher level of safety The optional TPAK magnetic hanger allows the user hands-free flexibility Specifications VCHEK 1,2,3 Range 6.000 V 60.00 V 600.0 V Resolution 0.001 V 0.01 V 0.1 V Accuracy DC, 45 to 500 Hz:2.0 % + 3 500 Hz to 1 kHz: 4.0 % + 3 Diode test 4 Range 2.000 V Resolution 0.001 V Accuracy 2.0 % + 3 Continuity4 Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer Ω4 Range 600.0 Ω 6.000 kΩ 60.00 kΩ Resolution 0.1 Ω 0.001 kΩ 0.01 kΩ Accuracy 0.9 % + 2 0.9 % + 1 0.9 % + 1 Capacitance4 Range 1000 nF 10.00 μF 100.0 μF 9999 μF Resolution 1 nF 0.01 μF 0.1 μF 1 μF Accuracy 1.9 % + 2 1.9 % + 2 1.9 % + 2 100 μF - 1000 μF: 1.9 % + 2 > 1000 μF: 5 % + 20 Notes: 1 All VChek voltage ranges are specified from 60 counts to 100 % of range. Because inputs below 60 counts are not specified, it is possible and normal for this and other True-RMS meters to display non-zero readings when the test leads are disconnected from a circuit or are shorted together. 2 Crest factor of ≤ 3 at 4000 counts, decreasing linearly to 1.5 at full scale. 3 Minimum measureable input in VCHEK autorange is 3 V dc. For measurements below 3 V dc, push Range button twice to get to 6 V dc manual range. 4 After measuring voltage, a wait time of 1 minute is required to maintain accuracy of ohms, capacitance, diode test, and continuity. Specifications Maximum voltage between any terminal and earth ground 600 V Display 3 3/4-digits, 6000 counts, updates 4/sec Operating temperature -10 °C to 50 °C (14 °F to 122 °F) Storage temperature -40 °C to 60 °C (-22 °F to 140 °F) Temperature coefficient 0.1 x (specified accuracy)/°C (< 18 °C or > 28 °C) Operating altitude 2,000 m Storage altitude 10,000 m Relative humidity 95 % to 30 °C 75 % to 40 °C 45 % to 50 °C Battery type 9 Volt Alkaline, ANSI 1604A / IEC 6F22 Battery life Alkaline: 300 hours typical, without backlight Shock 1 Meter drop per IEC 61010-1-2001 Vibration Per MIL-PRF-28800 for Class 2 instrument Size (HxWxL) 167.1 mm X 85.1 mm X 46.0 mm (6.58 in X 3.35 in X 1.81 in) Weight 13.0 oz (404 g) Safety Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 No 61010-1-04, UL 61010-1 (2004) and IEC/EN 61010-1 2nd Edition for measurement Category IV, 600 V, Pollution Degree 2, EMC EN61326-1 EMI regulations Complies with FCC Part 15, Class B Specifications VCHEK Input Impedance (Nominal) ~3 kΩ < 300 pF VCHEK Common Mode Rejection Ratio (1 kΩ Unbalanced) > 60 dB at dc, 50 or 60 Hz Ω Open Circuit Test Voltage < 2.7 V dc Full Scale Voltage < 0.7 V dc Diode test Open Circuit Test Voltage < 2.7 V dc Full Scale Voltage 2.000 V dc Ω Short Circuit Current < 350 μA Diode test Short Circuit Current < 1.0 mA
Item# FLUKE-113
$163.99
Availability: In stock