Electrical characteristics
(typical values relative to cells stored for one year or less at + 30°C max.)
Nominal capacity 2.1 Ah
(at 3 mA + 20°C 2.0V cut off. The capacity restored by the cell varies
according to current drain, temperature and cut off).
Open circuit voltage (at + 20°C) 3.67V
Nominal voltage (at 0.2 mA + 20°C) 3.6V
Pulse capability: Typically up to 120 mA (120 mA/0.1 second pulses,
drained every 2 mn at + 20°C from undischarged cells with 10 µA base
current, yield voltage readings above 3.0V. The readings may vary according
to the pulse characteristics, the temperature, and the cell's previous history.
Fitting the cell with a capacitor may be recommended in severe conditions.
Consult Saft)
Continuous current permitting 50% of the nominal capacity
to be achieved at + 20°C with 2.0V cut off. 25 mA
(Higher currents possible, consult Saft)
Storage (recommended) + 30°C (+ 86°F) max
(for more severe conditions, consult Saft)
Operating temperature range - 60°C/+ 85°C
(Operation above ambient T may lead to reduced capacity and (-76°F/+185°F)
lower voltage readings at the beginning of pulses. Consult Saft)
Physical characteristics
Diameter (max) 16.5 mm (0.65 in)
Height (max) 33.4 mm (1.31 in)
Typical weight 14.4 g (0.5 oz)
Li metal content approx. 0.6 g